DOC문서3-1. Item Requirements.docx

닫기

background image

Item Requirements

○ 

Article Name: Strain/Voltage Monitoring Equipment

○ 

Type and Quantity

Item No.

Item

Q'ty

1

16ch Strain/Voltage Compact Recorder
Includes :
- Input cable for strain and voltage 
- Bridge Box (16ch, 350ohm)
- AC Adapter 
- Control & Analysis software
- Battery Unit
- Remote Control Unit
- Carrying Case

1 set

○ 

Latest Delivery Date: 90 days from the Effective Date of Contract

○ 

Requirements 

General Feature

Compact   recorder   shal   support   standalone   recording   and   online   recording

through a LAN or USB connection. 

Modular   type   for   easy   expansion   and   up   to   128   channels.   16   channel

strain/voltage measuring unit shal  be included

Shock resistance: 490 m/s2 (50 G)

Al  channels synchronous 20 kHz (For 4 channels) Measurement of 1 channel at

max. 100 kHz

Synchronous   sampling   of   al   channels   shal   be   supported   with   minimum

frequency 1kHz

Rechargeable battery power unit mounted on the main body shal  be included to

supply electrical power during minimum 1 hour 

Main Unit

Data Saving location : PC & SD Card

Interface : USB 2.0, Ethernet

Measurement Setting method : Online (PC software), Offline (SD card)

Sampling : Max 100kHz


background image

Recording Mode : Manual, Trigger, Interval

Power : 10~30V DC, 100~240VAC (by AC Adaptor), Battery unit

Vibration resistance : 49 m/s2 (5 G)

Shock resistance   : 490 m/s2 (50 G)

Strain/Voltage Unit

Measuring targets : Strain gage, Strain gage transducer, Voltage

Bridge/Sensor Excitation : 2.5V DC

Measuring range 

 Strain ; Minimum 1000 X10-6 strain , Maximum 50000 X10-6 strain

 Voltage ; Minimum  1V, Maximum 50V

Accuracy : within ±0.1% FS

Battery Unit

Battery : Li-ion battery

Input DC : 10~30V DC

Output   : 10V DC

Discharging time : during 2.5A (25w) output ; 60min or more

Control Software

Y-time, X-Y, bar graphs, circular meters, and numeric display are possible

Measuring condition setting, data acquisition, data col ection, data reproduction

and file conversion. For analyzing the acquired data

Analysis Software

Al ow a data file to be processed for waveform display, FFT analysis, statistic

operations,  header information display,  tabulation  of numeric dataand setting

display conditions.

 

Extracts and converts the data files into CSV files.

 

Arithmetic   operations,   Histogram   analysis,   Filtering,   Differentiation   &

integration

 

Remote Control Unit

Operation Button : REC, STOP, BAL, OPTION1, OPTION2

Carrying Case

Inner Size : 55.3 X 42.4 X 27 cm

IP67 / Def Stan 81-41/STANAG 4280

Al  Standard accessories should be supplied

One year warranty


background image

○ 

Payment terms

  

Payment for the contract shall be made as fol ows:

Ratio

Payment terms

100%

Receipt of Invoice and Final Acceptance

of products by KARI