PDF문서RFP(Electro-Magnetic Susceptibility Test System).pdf

닫기

background image

 

KARI  PROPRIETARY 

 
 

Request for Proposal 

 

Electro-Magnetic Susceptibility Test 

System  

 

 

 

April, 2019 

 

Space Test Division 

Korea Aerospace Research Institute 

 

169-84 Gwahak-ro, Yuseung, Daejeon, 34133, KOREA 

Phone : 82(42)870-3739, Fax : 82(42)860-2234 

 

 

KARI  PROPRIETAR


background image

 

 

2019.04 

 

-2- 

 

PART I. Overview 

1.   Overview of the project  

1.1   KARI  has  a  satellite  assembly,  integration  and  test  center 

(hereinafter referred to as  “SITC”)  for  joint  use  by  corporations  and 

research  institutes  for  the  purpose  of  the  effective  development  of 

domestic  satellites.  And  basic  facilities  and  equipment  for  satellite 

assembly and test have been supplied, installed and used. 

1.2  The  purpose  of  this  project  is  to  equip  the  EMS  (Electro-Magnetic 

Susceptibility)  Test  System  for  EMI/EMC  measurement  including 

conducted  susceptibility  test  system,  radiated  susceptibility  test 

system. 

1.3   All  the  descriptions  in  this  RFP  are  minimum  requirements  and  the 

supplier  can  suggest  the  better  one  to  improve  the  overall 

performance  and  cost.  But  in  this  case,  the  proposal  should  clearly 

indicate the improvements 

from KARI’s requirements. 

 

2.  Procedures of the project 

2.1   The project shall be proceeded with five parts as follows: 

2.1.1 Organizations  of  conducted  susceptibility  test  system  and 

radiated susceptibility test system 

2.1.2 System design (reviews) and Factory acceptance test 

2.1.3 Transportation 

2.1.4 Installation at KARI 

2.1.5 Final acceptance test & training at KARI  

2.2   The participants shall submit the detailed work schedule for article 

2.2.1 Specially,  the  work  schedule  at  KARI  shall  be  confirmed  by 

KARI for avoiding overlap with KARI’ other test schedules. 


background image

 

 

2019.04 

 

-3- 

 

2.3   The participants shall submit 6 copies of a detailed proposal to KARI 

according  to  the  format  and  contents  satisfying  the  requirements 

stipulated in this RFP. 

2.4   The proposal shall include the followings;  

2.4.1  

Bidder’s qualification document 

2.4.2  Work schedule  

2.4.3  Compliance sheet to the requirement of this RFP 

2.4.4  Engineering work of overall system 

2.4.5  Design report, specification of components, detailed drawings  

2.4.6  Shipping, transportation, installation plan 

2.4.7  Acceptance test plan 

2.4.8  Training proposal 

2.4.9  Warranty and maintenance proposal 

2.4.10  Document list 

2.4.11  Price proposal 

2.5   The language for proposal shall be English or Korean. 

2.6   The  proposal  shall  be  delivered  to  KARI  before  the  due  date  for 

submission 

2.7   All proposals and documents submitted shall become the property of 

KARI. 

 

3.   Requisites of participants 

3.1   The participants shall supply information about themselves. 

3.2   The  participants  shall  have  experience  of  installation,  operation  and 

arranging of EMS Test System. 

3.3   The  supplier  shall  submit  the  business  showings  of  the 


background image

 

 

2019.04 

 

-4- 

 

manufacturing and installation of the EMS test system. 

 

4.   Scope of the contract 

4.1   The following items shall meet the specifications which are described 

in PART II, Technical Requirements. 

4.1.1  Conducted susceptibility test system 1 set (function generator, 

signal  generator,  oscilloscope  set,  active  current  &  voltage 

probe  set,  RF  switching  unit,  CS114  test  system  of  MIL-STD-

461F and 19

” system rack) 

4.1.2  Radiated susceptibility low frequency test system 1 set (signal 

generator,  RF  switching  unit,  power  meter  &  sensors,  field 

monitor  &  sensors,  RS103  test  system  of  MIL-STD-461F,  19

” 

system rack) 

4.1.3  Radiated susceptibility high frequency test system 1 set (signal 

generator,  RF  switching  unit,  power  meter  &  sensors,  field 

monitor  &  sensors,  RS103  test  system  of  MIL-STD-461F,  19

” 

system  rack  automatic/manual  antenna  mast,  measurement 

S/W and system controller) 

4.1.4  Acceptance test at factory & KARI site 

4.1.5  Project management, site operation, cooperation with KARI 

4.1.6  Basic principle, operation, warranty, maintenance, and training 

for the equipment    

4.1.7  Relevant  books  and  manuals,  documents  (data  sheet, 

drawings,  operation  manuals,  calibration  reports,  test  reports, 

and etc.) 

4.1.8  Other  necessary  matters  required  for  acquiring  and  installing 

the equipment 

4.2   The EMS test system shall  not have any problem for the installation 


background image

 

 

2019.04 

 

-5- 

 

in  KARI  test  site  and  connection  with  KARI’s  test  equipment,  in 

particular  the  power  amplifiers.  The  supplier  shall  design  the  test 

system with consideration for these constraints. 

 

 

PART II. Technical Requirements 

 

1.   System Configuration 

1.1   Conducted Susceptibility Test System 

No. 

Item 

Quantity 

Remark  

Function Generator 

1 ea 

 

Signal Generator 

1 ea 

 

Oscilloscope Set 

1 set 

 

Active Current & Voltage Probe Set 

1 set 

 

RF Switching Unit 

1 ea 

 

MIL-STD-461F CS114 Test System 

1 set 

 

19

” System Rack  

1 set 

 

 

1.2   Radiated Susceptibility Low Frequency Test System (9 kHz to 1 GHz) 

No. 

Item 

Quantity 

Remark  

Signal Generator  

1 ea 

 

Switching Unit   

1 ea 

 

Power Meter 

1 ea 

 

Power Sensor 

2 ea 

 

Field Monitor 

1 ea 

 

Field Probe 

1 ea 

 

19

” System Rack  

1 set 

 

 

 


background image

 

 

2019.04 

 

-6- 

 

1.3 Radiated Susceptibility High Frequency Test System (1 GHz to 18 GHz) 

No. 

Item 

Quantity 

Remark  

Signal Generator  

1 ea 

 

Switching Unit   

1 ea 

 

Power Meter 

1 ea 

 

Power Sensor 

2 ea 

 

Field Monitor 

1 ea 

 

Field Probe 

1 ea 

 

19

” System Rack  

1 set 

 

Automatic Antenna Mast 

1 ea 

 

Manual Antenna Mast 

2 ea 

 

10 

Measurement S/W 

1 set 

 

 

2.   Specifications 

2.1   Conducted Susceptibility Test System 

2.1.1  Function Generator (1ea) 

-  Waveform  modes  :  sine,  square,  pulse,  triangle,  ramp  and 

arbitrary waveforms(up to 256 kSa) 

-  Modulation types : AM, FM, PM, PWM, FSK 

Output voltage : up to 10Vpp (into 50 Ω)   

Output DC offset : ±5 mV to 5 V (into 50 Ω) 

-  Frequency range 

:10 μHz to 25 MHz @ sinewave 

-  Amplitude flatness : ±0.15 dB up to 10MHz @ sinewave 

-  Total  harmonic  distortion  :  0.04  %  (typ.)  up  to  100kHz  @ 

sinewave 

-  Phase noise : -115 dBc / Hz (typ.) 10kHz offset @ sinewave 

-  Ethernet/USB dual interface for remote control 

-  19" Rack adapter included 


background image

 

 

2019.04 

 

-7- 

 

2.1.2   Signal Generator (1ea) 

-  Frequency range: 9 kHz to 1.1 GHz   

-  Frequency Resolution of setting: 0.001 Hz  

-  Frequency sweep : min 0.001 Hz step size 

-  RF Power Level : -120 dBm to +18 dBm in 1 MHz < f  ≤ 1.1 

GHz  

-  Reverse power protection : 50W in 1 MHz < f ≤ 1 GHz 

-  Maximum permissible DC voltage : 35V 

-  Harmonics  :  -30  dBc  in  1  MHz  <  f  ≤  1.1    GHz  (  level  ≤  13 

dBm ) 

-  SSB Phase Noise: < 

–141 dBc, ( typ. –145 dBc) for f = 100 

MHz, level = 10 dBm, offset 20kHz  

-  Analog Modulation: AM, FM, PM, Pulse Modulation  

-  Pulse generator for modulation 

-  Interface: Ethernet/LAN, USB, GPIB 

-  19" Rack adapter included 

 

2.1.3   Oscilloscope Set (1 set) 

1)  Oscilloscope (1ea) 

-  Input channels: 4 channels 

Input impedance: 50 Ω ± 3.5 % ,1MΩ ± 1 %/15 pF 

-  Analog bandwidth (

–3 dB): 1 GHz 

Rise time/fall time: 280 ps, 10 % to 90 % at 50 Ω 

-  Input VSWR : 1.25 ≤ 2 GHz 


background image

 

 

2019.04 

 

-8- 

 

-  Vertical  resolution:  16  bit  (without  reduction  of  the  sampling 

rate)  @10 kHz to 50 MHz 

-  Inpu

t sensitivity at 50 Ω:1 mV/div to 1 V/div 

-  Channel-to-channel isolation : > 60 dB for ≤ 2 GHz 

-  Realtime  sampling  rate:  max.  10  GSample/s  on  each 

channel 

-  Realtime  waveform  acquisition  rate  :  >  1,000,000 

waveforms/s 

-  Memory  depth  :  50  MSample  on  4  channels  (200  MSample 

on 1 channel) 

-  Waveform math support 

-  Interface: LAN, USB, GPIB 

2)  Passive voltage probes (4 ea) 

500 MHz bandwidth, 10 MΩ || 9.5 pF input impedance 

-  10:1 Attenuation factor, max. 400 V  

3)  Active High voltage differential probes (3 ea) 

No 

Bandwidth 

Input 

impedance 

Attenuation 

factor 

Operating 

voltage 

Quantity 

100 MHz 

8 MΩ || 3.5 pF  100:1/1000:1 

±1400 V 

200 MHz 

5 MΩ || 2.5 pF 

25:1/250:1 

±750 V 

4)  Active current probes (1 ea) 

No 

Bandwidth 

Sensitivity 

Dynamic 
range 

Rise time 

Quantity 

100 MHz 

0.1 V/A 

30 A (RMS) 
±50 A (peak) 

3.5 ns 

 

 

 


background image

 

 

2019.04 

 

-9- 

 

2.1.4   RF Switching Unit ( 1 ea ) 

-  Base unit for EMS automatic test system 

-  Relay : 6 × coaxial relays(SPDT), failsafe, non-terminated  

-  Frequency Range: DC to 18GHz 

-  RF Connector : SMA female  

-  Insertion loss : < 0.7 dB  

-  Interface: LAN, USB, HDMI, Touch screen 

-  19" Rack adapter included 

 

2.1.5  BCI System for MIL-STD-461F CS114 (1 set) 

1)  Current Injection Clamp probe (1ea) 

-  Frequency Range: 10 kHz to 400 MHz 

-  Inner diameter: 40 mm 

-  Input Power rating: 100 W for 30 min.( 200 W for 5 min.) 

2)  Current Injection Probe Calibration Fixture (1ea) 

-  Frequency Range: 10 kHz to 450 MHz 

-  Compatible with current injection clamp probe 

3)  Current monitoring clamp probe (1ea) 

-  Frequency Range: 1 kHz to 500 MHz 

-  Inner diameter: 40 mm 

-  Outer diameter : 98 mm 

-  Height : 38 mm 

Transfer impedance : 0 dBΩ with 50 Ω load impedance 

-  Handling current : 200 A 

-  Peak pulse current: 100 A 


background image

 

 

2019.04 

 

-10- 

 

4)  Current monitoring probe Calibration Fixture (1ea) 

-  Compatible with current monitoring clamp probe 

5)  Power RF attenuator (1ea) 

-  Frequency Range: DC to 3 GHz 

-  Attenuation : 20 dB 

-  Power rating : 150 W 

-  Connector : N type female to N type female 

6)  Power  Load Resistor (1ea) 

-  Power rating: 150W 

-  Frequency Range: DC to 2.4GHz 

-  Connector : N type female 

7)  RF cable set for BCI test (1 set) 

-  BNC/N-type RF cables for BCI test system 

-  RF connectors and adapters for BCI test system 

8)  Directional Coupler (1 ea) 

-  Frequency : 9 kHz ~ 400 MHz 

-  Coupling factor : 40 ± 0.5 dB 

-  Handling power : 200 W min. 

 

2.1.6  19

” System Rack (1 set) 

-  Custom made by CS test system design 

-  19

”, 24 HU Rack system, Line distribution unit & Exhaust fan 

included 

-  RF  cable  set  for  inside  system  rack,  RF  connectors  and 

adapters, RF cables for conducted susceptibility test  


background image

 

 

2019.04 

 

-11- 

 

-  System controller included for test automation : windows 10, 

i7 or higher CPU, min. 4 GB memory, min 1T HDD 

The system rack shall have a space to equip  KARI’s power 

amplifiers.  All  the  cables  and  accessories  for  connection 

between  test  system  and  power  amplifiers  shall  be  also 

included. 

 

2.2   Radiated  Susceptibility  Low  Frequency  Test  System  (9  kHz  to  1 

GHz) 

2.2.1   Signal Generator (1ea) 

-  Frequency range : 9 kHz to 1.1 GHz   

-  Frequency resolution of setting : 0.001 Hz  

-  Frequency sweep : min 0.001 Hz step size 

-  Aging : < 1 × 10–6/year 

-  Specified level range : 

–120 dBm to +13 dBm @ 200 kHz < f 

≤ 1 MHz 

-  Reverse power protection : 50 W in 1 MHz < f ≤ 1 GHz 

-  Maximum permissible DC voltage : 35 V 

-  Harmonics : < -30 dBc in 1 MHz < f ≤ 1.1  GHz ( level ≤ 13 

dBm ) 

-  SSB Phase Noise : < 

–141 dBc, ( typ. –145 dBc) for f = 100 

MHz, level = 10 dBm, offset 20 kHz 

-  Analog Modulation : AM, FM, PM, Pulse Modulation 

-  Pulse modulator, pulse generator included 

-  Interface : Ethernet/LAN, USB, GPIB 

-  19" Rack adapter included 


background image

 

 

2019.04 

 

-12- 

 

 

2.2.2   Switching Unit (1ea) 

-  Base unit for EMS automatic test system 

-  1 touch screen display  

-  Relay  :  6  ×  coaxial  changeover  relays  (SPDT),  SSR(Solid-

state relays), non-terminated 

-  Frequency Range: 9 kHz to 6 GHz 

-  RF Connector : SMA female  

-  Interface: LAN, USB, HDMI, micro SD card 

-  Remote control via LAN 

-  Digital I/O module: 16 × digital inputs, 16 × digital outputs 

-  19" Rack adapter included 

 

2.2.3   Power Meter (1ea) 

-  Measurement Channel : 2 channels 

-  Frequency Range : DC to 110 GHz (sensor dependent) 

-  Power  measurement  Range  :  0.1  fW  to  30  W  average 

(sensor-dependent) 

-  Interface: GPIB, LAN, USB 

5’’ touch display (800 x 480 pixel) 

-  19" Rack adapter included  

 

2.2.4  Power Sensor  (2ea) 

-  Frequency Range: 8 kHz to 6 GHz 

-  Power measurement Range : 100 pW to 200 mW (

–70 dBm 


background image

 

 

2019.04 

 

-13- 

 

to +23 dBm) 

-  SWR : < 1.13 (1.11) @ 20 kHz to 2.4 GHz 

-  Max Power : average 1 W (+30 dBm), max. 10 V dc 

-  Power sensor cable included 

-  Connector : N male 

 

2.2.5   Field Monitor (1ea) 

-  Sensitivity : 0.4 to 1400 V/m (probe dependent) 

-  Frequency Response : 5 kHz to 60 GHz (probe dependent) 

-  Interface : GPIB, USB, LAN 

-  Input : up to 4 independent probes  

-  19" Rack adapter included 

 

2.2.6   Field Probe (1ea) 

-  Frequency range : 100 kHz to 6 GHz 

-  Amplitude Accuracy : ±1.0 dB @ 10 MHz Without correction 

factors applied 

-  Operating Range 

∙  0.5 to 800 V/m @ 100 kHz to 1 GHz 

∙  0.5 to 600 V/m @ 1 GHz to 4 GHz 

∙  0.7 to 800 V/m @ 4 GHz to 6 GHz 

-  Linearity, 0.5 to 800 V/m : ±0.5 dB and ±0.3 V/m 

-  Data returned from probe : X, Y, Z axes and composite 

-  Power requirements : Laser powered from interface 

-  Field probe interface included 


background image

 

 

2019.04 

 

-14- 

 

 

2.2.7 19

” System Rack (1 set) 

-  Custom made by RS test system design 

-  19

”, 32 HU Rack system, Line distribution unit & Exhaust fan 

included 

-  RF  cable  set  for  inside  system  rack,  RF  connectors  and 

adapters, RF cables for radiated susceptibility test  

-  The  system  rack  shall 

be  connected  with  the  KARI’s  power 

amplifiers  installed  in  amplifier  room.  All  the  cables  and 

accessories  for  connection  between  test  system  and  power 

amplifiers shall be also included. 

 

2.3   Radiated  Susceptibility  High  Frequency  Test  System  (1  GHz  to  18 

GHz) 

2.3.1   Signal Generator (1ea) 

-  Frequency range : 100 kHz to 20 GHz   

-  Frequency resolution of setting : 0.001 Hz  

-  Frequency sweep : min 0.001 Hz step  size 

-  Aging : < 1 × 10–6/year 

-  Specified level range : 

–120 dBm to +11 dBm @ 50 MHz < f 

≤ 20 GHz 

-  Reverse power protection : 50 W in 1 MHz < f ≤ 1 GHz 

-  Maximum permissible DC voltage : 35 V 

-  Harmonics : < -30 dBc in  f > 1 MHz ( level ≤ 8 dBm ) 

-  SSB Phase Noise :  


background image

 

 

2019.04 

 

-15- 

 

∙  < –122 dBc (typ. –128 dBc) for f = 1 GHz, offset 20 kHz 

∙  < –102 dBc (typ. –108 dBc) for f = 10 GHz, offset 20 kHz 

∙  <  –96 dBc (typ. –102 dBc) for f = 20 GHz, offset 20 kHz 

-  Analog Modulation : AM, FM, PM, Pulse Modulation  

-  Pulse modulator, pulse generator included 

-  Pulse Train Support 

-  Interface : Ethernet/LAN, USB, GPIB 

-  19" Rack adapter included 

 

2.3.2   Switching Unit (1ea) 

-  Base unit for EMS automatic test system 

-  Small status display 

-  Relay  :  6  ×  coaxial  changeover  relays  (SPDT),  non-

terminated, failsafe 

-  Frequency Range: DC to 40 GHz 

-  RF Connector : 2.92 mm female  

-  Interface: LAN, USB, HDMI, micro SD card 

-  Remote control via LAN 

-  19" Rack adapter included 

 

2.3.3   Power Meter (1ea) 

-  Measurement Channel : 2 channels 

-  Frequency Range : DC to 110 GHz (sensor dependent) 

-  Power  measurement  Range  :  0.1  fW  to  30  W  average 

(sensor-dependent) 


background image

 

 

2019.04 

 

-16- 

 

-  Interface: GPIB, LAN, USB 

5’’ touch display (800 x 480 pixel) 

-  19" Rack adapter included  

 

2.3.4   Power Sensor  (2ea) 

-  Frequency Range : 50 MHz to 18 GHz 

-  Power measurement Range : 1 nW to 100 mW (

–60 dBm to 

+20 dBm) @ continuous average 

-  SWR : < 1.20 (1.18) @ > 2.4 GHz to 8.0 GHz  

-  Max power 

∙  Average power : 0.2 W (+23 dBm), continuous 

∙  Peak power : 1 W (+30 dBm) for max 1 μs 

-  Connector : N male 

 

2.3.5   Field Monitor (1ea) 

-  Sensitivity : 0.4 to 1400 V/m (probe dependent) 

-  Frequency Response : 5 kHz to 60 GHz (probe dependent) 

-  Interface : GPIB, USB,LAN 

-  Input : up to 4 independent probes  

-  19" Rack adapter included 

 

2.3.6   Field Probe (1ea) 

-  Frequency range : 2 MHz to 40 GHz 

-  Amplitude Accuracy : ±1.0 dB @ 10 MHz Without correction 

factors applied 


background image

 

 

2019.04 

 

-17- 

 

-  Operating Range : 2 to 1000 V/m 

-  Linearity, 2 to 1000 V/m : ±0.5 dB 

-  Damage level : 1200 V/m CW 

-  Data returned from probe : X, Y, Z axes and composite 

-  Power requirements : Laser powered from interface 

-  Field probe interface included 

 

2.3.7   19

” System Rack (1 set) 

-  Custom made by RS test system design 

-  19

”, 32 HU Rack system, Line distribution unit & Exhaust fan 

included 

-  RF  cable  set  for  inside  system  rack,  RF  connectors  and 

adapters, RF cables for radiated susceptibility test  

The system rack shall have a space to equip  KARI’s power 

amplifiers.  All  the  cables  and  accessories  for  connection 

between  test  system  and  power  amplifiers  shall  be  also 

included. 

 

2.3.8   Automatic Antenna Mast (1ea) 

-  Adaptors for up to 5 horn antennas 

-  Polarization, height & positioning control 

-  Adjustable height : 0.7 m ~ 1.5 m 

-  Max horizontal movement : 1458 mm 

-  Control  options  :  HMI  touch  screen,  remote  control  module 

via fiber optic 

 


background image

 

 

2019.04 

 

-18- 

 

2.3.9   Manual Antenna Mast (2ea) 

-  Manual antenna mast shall be able to  install the 9120F and 

3106B Horn Antenna.  

-  Adaptor for 3106B included 

 

2.3.10  System Control and Measurement S/W (1set) 

-  measurement of radiated and conducted susceptibility                                           

-  use in product certification and testing during development                                     

-  in line with military standards     

-  fully automatic control of EMS test system components                                         

-  integrated calibration concept                                                                  

-  flexible report generator (HTML, RTF, PDF)  

-  software operates as a virtual instrument                                                    

-  direct power injection measurements                                                       

-  several antenna polarizations                                                                  

-  generic device drivers support 

-  System controller included for test automation : windows 10, 

i7 or higher CPU, min. 4 GB memory, min 1T HDD 

 

3.  Acceptance Test and Training  

3.1  System Performance Test  

3.1.1  Performance  test  of  the  EMS  test  system  shall  be  conducted 

before delivering to customer. 

3.1.2  Following items shall be verified and reported to customer.  

-  Interoperability with KARI

’s equipment (power amplifiers and 


background image

 

 

2019.04 

 

-19- 

 

spectrum analyzer) in EMS test system 

-  Functional and performance test in fully integrated EMS test 

system(not  individual  equipment)  including  new  automatic 

control  software  :  signal  generation,  monitoring,  remote  & 

automatic  control,  date  reporting,  user  convenience,  heat 

exhaust, etc. 

3.1.3  System  performance  test  is  based  on  the  CS114/RS103  test 

of the MIL-STD-461F. Recommendations for different technical 

verification  with  clear  reasons  are  accepted.  Supplier  shall 

support all necessary equipment and test facility.  

3.1.4  Supplier  shall  provide  detailed  test  procedures,  items  and 

methods  to  KARI  before  performance  test,  and  test  reports 

after performance test. 

  

3.2   Site Acceptance Test 

3.2.1  Following acceptance tests shall be performed for all delivered 

test systems in KARI site. 

-  Unpacking 

-  Visual inspection 

-  Installation of the test system in EMC chamber of KARI 

(Including  the  installation  and  con

nection  of  KARI’s 

equipment) 

-  System automatic control by software 

-  Performance check for acceptance 

3.2.2  EMS  test  system  shall  be  fully  operated  and  verified  its 

performance as followings; 

-  Signal  generation  (current  /voltage  signal,  electric  field 

signal)  


background image

 

 

2019.04 

 

-20- 

 

-  Monitoring of signals (current/voltage, power, electric field) 

-  System control by software (remote & automatic) 

-  Data reporting and presentation 

-  Test shall be performed according to the CS114/RS103 test 

of MIL-STD-461F. 

3.2.3  Detailed test procedures, items and methods shall be provided 

by supplier, and confirmed by KARI before acceptance test. 

 

3.3 Training for operation 

3.3.1  Supplier  shall  provide  operation  manuals,  procedures  or 

relevant documents for training. 

3.3.2  Training  of  EMS  test  systems  shall  be  provided  by  well-

experienced engineer for more than 1 weeks. 

 

4.   Remarks 

4.1    Warranty  :  1  years  warranty  for  test  system,  3  years  warranty  for 

measurement equipment 

4.2   All test system and test equipment shall be powered by single phase 

220V, 60 Hz, 16A. 

4.3   Test  system  shall  not  include  any  Ro

HS  Material  to  harm  user’s 

health. 

4.4   Supplier  shall  provide  acceptance  test  results(reports)  of  EMS  test 

system to KARI.