PDF문서4. Technical Requirement.pdf

닫기

background image

REQUIREMENTS  OF

  S-BAND  UP  AND  DOWN  CONVERTERS

A. OVERVIEW

    This  document  describes  all  requirements  related  to  S-Band  up  converter 

and  Down  converter  which  is  going  to  be  ordered  by  in  KARI. 

1. Delivery  Schedule    :  Up  to  31,  December,  2018

2. Delivery  Place  :  Republic  of  Korea  Aerospace  Research  Institute,

                                    Satellite  Operation  &  Application  Center

3. Warranty  :  1Year

4. Delivery  Equipment  and  requirements

1)  S  Band  Down  Converter    :  2EA  as  below  Model

2)  S  Band  UP  Converter  :  2EA  as  below  Model

3)  Contractor  must  be  provides  installation  and  test  results  of  specification

4)  For  installation,  contractor  must  be  support  and  provide  S/W  and  H/W 

interface  test  between  delivered  equipments  and  operated  system

5)  For  test  results,  contractor  must  be  provide  electronic  test  result  of   

providing  by  manufactor

Model  Number

Manufacture 

S  Band  D/C

(DTR-200240-6002044)

GeoSync

S  Band  U/C

(UTR-200240-6002044)

Geosync


background image

 

B. Specifications

  MITEQ  S  Band  Down  Converter  (DTR-200240-6002044)

Items

SPECIFICATIONS 

1. Input  Frequency

2000MHz  ~  2400MHz

2. Input  Impedance

50Ω

3. Input  Return  Loss

20dB  min

4. Output  Frequency

70MHz  (±20MHz)

5. Output  Impedance

50Ω,

6. Output  Return  Loss

26dB  min

7. Power  Output  (P1dB)

+16dBm  min

8. Gain

40dB

9. Noise  Figure

11dB  max

10. Amplitude  response

±0.5dB  p-p/±20MHz,  ±0.2/±18MHz

11. SW  ICD

appllicable  9400,  9600,  9800

12. Gain  Slope

0.03dB/MHz  max  (10MHz  max)

13. Gain  adjustment

30dB  in  0.2dB  steps

14. Frequency  stability

±2*10ˉ

8,0  to  50°C

15. External  reference

5  or  10MHz,  4  ±3dBm  Unit  will  automatically  switch  to  internal 

reference  if  external  reference  level  falls  below  +1dBm  nominal

16. Primary  power

90  ~  250VAC

17. Remote  Interface

RS232,  Ethernet
RS-232  &  Ethernet  (RS232  and  Ethernet  Interface)
RS232  could  be  altered  into  RS422/485  if  necessary.

18. Remote  Protocol

 

interface  protocol  must  be  compatible  with  operated  Model  MITEQ 

9400  ,9600,  9800 

19. Dimension

Hardware  interface  must  be  compatible  with  operated  Model  MITEQ 

9400  ,9600,  9800 

20. AC  INPUT

100~220VAC  Free  voltage

21. Ethernet  Interface

10/100  Base-T  Ethernet  interface  providing:

HTTP-based  web  server

SNMP1.0  configuration

Alarm  reporting  via  SNMP  TrapPassword  protection


background image

MITEQ  S  Band  UP  Converter  (UTR-200240-6002044)

Items

SPECIFICATIONS

1. Input  Frequency

70MHz

2. Input  Impedance

50Ω

3. Input  Return  Loss

20dB  min

4. Output  Frequency

2,000~2400MHz

5. Output  Impedance

50Ω,   

6. Output  Return  Loss

20dB  min

7. Power  Output  (P1dB)

+16dBm  min

8. Gain

30dB

9. Amplitude  response

±0.25/±20MHz,  ±0.2/±18MHz

10. SW  ICD

appllicable  9400

11. Gain  Slope

0.03dB/MHz  max  (10MHz  max)

12. Gain  adjustment

30dB  in  0.2dB  steps

13. Frequency  stability

±2*10ˉ

8,0  to  50°C

14. External  reference

5  or  10MHz,  4  ±3dBm  Unit  will  automatically  switch  to  internal 

reference  if  external  reference  level  falls  below  +1dBm  nominal

15. Primary  power

90  ~  250VAC

16. Remote  Interface

RS232,  Ethernet

RS-232  &  Ethernet  (RS232  and  Ethernet  interface)

RS232  could  be  altered  into  RS422/485  if  necessary.

17. Remote  Protocol

interface  protocol  must  be  compatible  with  operated  Model  MITEQ 

9400  ,9600,  9800 

18. Dimension

Hardware  interface  must  be  compatible  with  operated  Model  MITEQ 

9400  ,9600,  9800 

19. AC  INPUT

100~220VAC  Free  voltage

20. Ethernet  Interface

10/100  Base-T  Ethernet  interface  providing:

HTTP-based  web  server

SNMP1.0  configuration

Alarm  reporting  via  SNMP  TrapPassword  protection