Technical Requirements
○ Article Name: Cryogenic Globe Valves
○ Order Information
No. Item
Requirements
Q'ty
1
DN 15 Pneumatic
Cryogenic Globe
Valves
- Cryogenic (-196℃~50℃),
- Pneumatic,
- On/Off,
- Normally closed,
- LN2, PN 12 or higher,
- Kv Valve more than 1.89m3/h
6ea
2
DN 25 Pneumatic
Cryogenic Globe
Valves
- Cryogenic (-196℃~50℃),
- Pneumatic,
- On/Off,
- Normally closed,
- LN2, PN 12 or higher,
- Kv Valve more than 8m3/h
6ea
3
DN 50 Pneumatic
Cryogenic Globe
Valves
- Cryogenic (-196℃~50℃),
- Pneumatic,
- On/Off,
- Normally closed,
- LN2, PN 12 or higher,
- Kv Valve more than 32.3m3/h
2ea
4
DN 50 Pneumatic
Cryogenic Regulation
Valve
- Cryogenic (-196℃~50℃),
- Pneumatic,
- On/Off,
- Normally closed,
- LN2, PN 12 or higher,
- Kv Valve more than 32.3m3/h
1ea
○ Delivery Date : Within 12Weeks After Receipt of Order
○ Contractor shall provide to KARI the documents of Certificate of Conformity (CoC), LN2
test results, leak test results and manual on the delivery of above Items
○ Warranty Period : 1 year after the delivery of Items