PDF문서Specifications(2017-0123).pdf

닫기

background image

S p e c if ic a t io n s

작성일자 : 2017. 2. 7.

영문 : Procurement of Elastomeric Lead-lag Dampers of

Small Scale Rotor Hub for Rotor Wind Tunnel Test

모 델 명

Elastomeric lead-lag damper

세부 사양

(1) Configuration

- Damper length between two rod end bearings is 85mm.
- The diameter or width of damper is less than 35mm.

(2) Damper loads

- Damper should withstand the maximum tension load of 600N and the

maximum compression load of 900N.

(3) Stiffness and damping

- Elastomeric dampers have the characteristics of elastic and damping and

complex stiffness is expressed as follows

K* = K' + j×K"

- Target stiffness and damping values of a damper

- Primary operating frequency for damper design is 1/rev and damper should

be designed to match the target values of stiffness and damping at 1/rev
requirements within 20% tolerance.

(4) Test

- Acceptance test reports for dampers should be provided.

Frequency

K′ (N/mm)

K (N/mm)

14.4 Hz(0.5/rev)

239

67

28.7 Hz(1/rev)

327

100