KARI  PROPRIETARY 

 

Request For Proposal 

for 

Acoustic Testing at KARI Chamber 

 

 

 

October 2014 

 

Space Environment Test Team 

Korea Aerospace Research Institute 

 

169-84 Gwahangno, Yuseong-gu, Daejeon, 305-806, KOREA 

Phone : 82(42)860-2562, Fax : 82(42)860-2234 

 

 

KARI  PROPRIETARY 


background image

 
 

Request For Proposal 

for 

Acoustic Testing at KARI Chamber  

 
 

 

IMPORTANT 

 

1. This RFP should be kept in confidentiality and should neither 
be copied nor distributed to the third parties. 

 

2. The  questions  and  opinions  on  this  RFP  can  be  asked  or 
suggested  to  Korea  Aerospace  Research  Institute  before 
submission of the proposal. 

 

3. This  RFP  should  be  returned  to  Korea  Aerospace  Research 
Institute with bidder

’s proposal. 

 

4. This  RFP  shall  be  legal  bind  after  the  contract  is  awarded 
unless  the  bidder  explicitly  expresses  the  differences  from  the 
RFP in the compliance sheet. 

 

 

 

October 2014 

 
 

Space Environment Test Team 

 

Korea Aerospace Research Institute 

 

169-84 Gwahangno, Yuseong-gu 

DAEJEON, 305-806, KOREA 

 
 

Phone : 82(42)860-2562, FAX : 82(42)860-2234 

e-mail :acoust@kari.re.kr 


background image

 

 

2014. 10 

 

 
 
 

Space Environment Test Dept. 

Table of Contents 

 

I. 

OVERVIEW ............................................................................................................................. 2 

1. 

OVERVIEW OF THE PROJECT ..................................................................................................... 2 

2. 

REQUISITES OF PARTICIPANTS .................................................................................................. 2 

3. 

SCOPE OF THE CONTRACT ........................................................................................................ 2 

II. 

TECHNICAL REQUIREMENTS ...................................................................................... 3 

1. 

TOTAL SYSTEM CONFIGURATION ............................................................................................. 3 

2. 

REQUIREMENTS FOR ACOUSTIC TESTING ................................................................................. 4 

 


background image

 

 

2014. 10 

 

 
 
Acoustic testing at KARI Chamber 

2           

Space Environment Test Dept.

 

 

I.  OVERVIEW 

 

1.  Overview of the project 

 

1.1 

Korea Aerospace Research Institute 

(hereinafter referred to as “KARI”) is located 

at Daeduk Research Complex, 140 km south of Seoul. 

 

1.2 

KARI has a satellite assembly, integration and test center (hereinafter referred to 

as “AITC”) for joint use by corporations and research institutes for the purpose of 

the  effective  development  of  domestic  satellites.  And  basic  facilities  and 

equipment for satellite assembly and test have been supplied, installed and used. 

 

1.3 

The purposes of this project is to perform the acoustic test with acoustic source of 

contractor in KARI acoustic chamber system. 

 

1.4 

All the descriptions in this RFP are minimum requirements and the supplier can 

suggest the better one to improve the overall performance and cost. But in  this 

case,  the  proposal  should  clearly  indicate  the  improve

ments  from  KARI’s 

requirements. 

 

2.  Requisites of participants 

 

2.1 

The  participants  shall  also  have  experience  of  manufacturing,  integration, 

installation and operation for acoustic chamber of over 1,000m3. 

 

3.  Scope of the contract 

 

3.1 

The Contract shall supply the following; 

 

  Perform acoustic testing in KARI with specified test spectrum 

  Supply the acoustic test report 

  Supply the facility safety logic 

 

 


background image

 

 

2014. 10 

 

 
 
Acoustic testing at KARI Chamber 

3           

Space Environment Test Dept.

 

 

II.  Technical Requirements 

 

1.  Total System configuration 

 

The  size  of  KARI  acoustic  chamber  is  volume  of  1,200m3  .Two  acoustic  sources  are 

equipped in chamber to generate the high intensity acoustic test. For the low frequency 

excitation, WAS 3000 is installed on the 25Hz acoustic horn. 

 

 

 

Figure 1 KARI Acoustic Chamber 

 

 

 


background image

 

 

2014. 10 

 

 
 
Acoustic testing at KARI Chamber 

4           

Space Environment Test Dept.

 

 

2.  Requirements for acoustic testing 

 

2.1  KARI interface requirements for acoustic testing 

Contractor  shall  supply  the  required  all  interfaces  to  perform  the  acoustic 

testing with acoustic source of contractor. 

KARI  don’t  supply  the  additional  interface  or  modification  of  facility  to 

contractor. 

Contractor shall send the acoustic engineers to perform the acoustic test with 

KARI engineers. 

     

  GN2 flow rate supplied to acoustic source : Max. 2.5kg/sec at 2 bar       

  Electrical power : 220 Volts 

  Acoustic chamber volume : 1,200m3 

  Amplifier of WAS 3000 & Interface [Refer to Figure 2 ] 

  Acoustic horn and pipe interface [Refer to Figure 3] 

  Acoustic controller : KARI software & M+P controller 

 

 

 

Figure 2 Amplifier of WAS 3000 & Interface 


background image

 

 

2014. 10 

 

 
 
Acoustic testing at KARI Chamber 

5           

Space Environment Test Dept.

 

 

 

Figure 3 Acoustic horn and pipe interface 

 

2.2  Acoustic testing requirements 

 

With the acoustic source of contractor, contractor shall perform the acoustic 

test  in  KARI  site  and  show  the  satisfaction  of  the  test  spectrum  within  the 

tolerance defined in Table 1.   

Contractor shall install the acoustic source and interface 

Contractor shall use the Low & High frequency sources 

KARI  engineer  shall  perform  the  acoustic  control  under  the  participation  of 

engineer of contractor     

Performance test period is 4 days in KARI 

Acoustic test shall be performed until 20th of February of 2015. 

After finishing the acoustic test, contractor shall supply the test report   

 

Figure 4. Acoustic spectrum [1/3 octave band] 


background image

 

 

2014. 10 

 

 
 
Acoustic testing at KARI Chamber 

6           

Space Environment Test Dept.

 

 

Table 1 Acoustic test requirement for spectrum and tolerance at KARI Chamber 

 

 

2.3  Logical diagram for safety system 

 

Contract shall supply the logical diagram for safety on KARI vibration facility   

After analyzing the KARI facility components, make a logical diagram for safe 

testing 

 

2.4  Deliverable items   

  Acoustic test report   

  Logical diagram for safety system   

25

132

+3/-3

31.5

139

+3/-3

40

140

+3/-3

50

143

+3/-3

63

145

+3/-3

80

144.5

+3/-3

100

144.4

+3/-3

125

144.3

+3/-3

160

144.2

+3/-3

200

144

+3/-3

250

143.5

+3/-3

315

144

+3/-3

400

143

+3/-3

500

141

+3/-3

630

139

+3/-3

800

138

+3/-3

1000

137

+3/-3

1250

136

+3/-3

1600

134

+3/-3

2000

132

+3/-3

2500

131

+3/-3

OVSPL

155

+1/-3

Test Spectrum

Tolerance

1/3 Freq (Hz)