Commodity  :  SAS  (Solar  Array  Simulator)

-  H/W  :Solar  Array  Simulator

-  S/W  :  Controller  (To  control  SAS)

-  Rack

1.  Delivery

:  Within  Five  Months  after  Contract

                ①   On  delivery  H/W  and  S/W  separated  :

                      →   After  H/W  delivered  first,  S/W  Acceptance  Test 

shall  be  completed  within  Two  months.

                ②   On  delivery  H/W  and  S/W  combined  :

                      →   Acceptance  Test  shall  be  completed  within  Three 

months  since  the  Contract  date.

2  Functional  Requirement

2.1  Power  Characteristics

1)  Voc  :  >  101.58V

2)  Isc:  >  24.05A

3)  Vmp  :  92V

4)  Imp  :  23.51A

5)  Pmax  :  >  2163.09W

6)  MPPT  Accuracy  :  2%

7)  MPPT  Response  Time 

Peak  Voltage  response  :  shall  be  guaranteed  up  to  200  Hz

Peak  Current  response  :  shall  be  guaranteed  up  to  200  Hz

Peak  Power  response:  shall  be  guaranteed  up  to  400Hz

2.2  Communication

1)  10/100  Base-T  Ethernet  LAN  Interface

2)  GPIB  interface  Standard  shall  be  provided

2.3.  Protection  Features

1)  Over-voltage,  Over-current,  Over-temperature  protection

2.4.  System  Control  Tools


background image

1)  In  order  to  Control  the  Configuration,  Parameter  Setting  and 

Monitoring,  System  Control  Tools  shall  be  provided.

2)  The  display  figure  of  the  System  Control  Tools  shall  be  designed 

as  like  the  existing  SAS  (KARI  -  Old  Model).  (Output  Power  Display, 

Alarm,  etc)

3)  Access  Mode  shall  has  two  control  mode  -  Local  Mode  and  Remote 

Mode.

2.5.  Server  Control  allows  access  to  the  System

1)  SAS  shall  be  able  to  be  accessed  from  Server  such  as  another 

equipment.

2.6.  The  interface  (including  S/W)  between  PACE  (Power  And  Control 

Equipment  -  KARI  having)  and  SAS  shall  be  provided.

2.7.  The  hardware  interface  of  SAS  shall  be  concerned  for  utilizing 

the  existing  cables  (Power  Cables  and  Monitoring  CAbles).

2.8.  SAS  Basic  H/W  Specification

1)  Power  :  380  VAC  3Ø  5Wire

2)  Output  Power  shall  be  assigned  to  Connector  J1  and  the  Type  of 

connector  shall  be  31pin  Circular  Socket  with  the  equivalent  level 

to  Mil-std.

3)  Power  Status,  One  of  the  Communicating  information  between  PASE 

and  SAS,  shall  be  utilized  as  the  equivalent  level  to  Mil-std.  The 

Connector  shall  be  19  Pin  Circular  Pin  Type.

2.9  Rack  Manufacture

2.9.1  Rack  shall  be  manufactured  under  the  specifiaction  of 

EIA-RS310-C,  IEC-297-1  and    DIN-4149.

2.9.2  The  size  of  the  Rack  shall  be  designed  as  the  following  figure 

2.  Rack  Conceptual  Design  diagram.

1)  One  Bay  19inch

2)  I-Bolt  (M12)  shall  be  installed  at  top  of  the  rack.